Options for Failed Sirsi Serial Control/Issues Records
OCLS and Ex Libris have been exploring options to address the failed Sirsi serial control/issues records. Please review the options presented below and consider doing some analysis to see which option is best for your college. When your preferences for your data extracts are due on April 26th, you will need to finalize your decision on your match point for cutover. More information about where to input your preferences will be coming soon.
Test Load Issue
In the test load, some colleges’ serial control/issues records failed because the SERC_TITLE_KEY in serial control records cannot find a match in 020, 022, or 035 fields of bib records.
SERC_TITLE_KEYs are auto generated in Sirsi when loading records using the Load Bibliographic Records report or via SmartPort, or when adding titles directly. They can be control numbers from 001, 010, 020, 022, 024, or 035, or they can be from catalog keys. These keys cannot be changed.
Dealing with Leading Letters
Ex Libris did some extra testing and said they would be able to match SERC_TITLE_KEYs to not only 020, 022, or 035 fields of bib records, but also 004 field (cat key) for the cutover. If colleges choose to continue using SERC_TITLE_KEYs as match point for serial control records for the cutover, they will need to specify if they would like Ex Libris to ignore the leading letter in SERC_TITLE_KEYs (e.g. s0277-867X, a51910), or they would like Ex Libris to include the leading letter in SERC_TITLE_KEYs when matching.
Recommendation for SISAC_ID as Match Point
Alternately, if your library consistently uses ISSN (022) as SISAC_ID for serial control records, OCLS highly recommends that you consider using SISAC_ID as the match point for the cutover instead of SERC_TITLE_KEY.
SISAC_ID in Sirsi is intended to contain ISSN, OCLS believes all colleges are following this practice. Your cataloguers may be able to tell you what their practices are or you can check your data. If you can confirm you follow this practice, you may not need to do any checks. Otherwise, you can conduct some random checks or a thorough check.
How to Check for SISAC_ID
If you would like to do random or thorough checks, one way to start is with the College_serial_control_YYYYMMDD.txt file we delivered last October. You can do a search for “SISAC_ID” in the .txt file using Notepad + + and see if they look legitimate (they should all be in the form of xxxx-xxxx). Then check the corresponding serial control records and bib records/title records in Sirsi Workflows. If a 022 in a bib record/title record is always used as SISAC_ID in the corresponding serial control record, it should be safe to say that SISAC_ID is a better match point for your library.
Example SISAC_ID Check
Below are our steps when we did some random checks (an example from Georgian). If you find better ways to do these checks, please share them with other colleges.
Step 1: Open the College_serial_control_YYYYMMDD.txt file using Notepad ++, do a search with “SISAC_ID”. It gives a list of SISAC_IDs.
Step 2: Search the SISAC_ID in the Sirsi Workflows using the Display Control wizard in the Serial Control module.
Step 3: Use the Item Search and Display wizard to locate the same title’s bib record, and make sure the SISAC_ID is indeed in the 022 field:
Step 4: If you find that SISAC_ID is different from 022 in the title record/bib record, you should use 022 as SISAC_ID. You can change SISAC_ID in serial control using the Modify Control wizard in the Serial Control module.
If you have questions, please comment below and tag Jennifer Mo (Jennifer Mo (Unlicensed)) in your comment.